Product category

ACMELEC AcmeLink VRF Gateways

AcmeLink is ACMELEC’s HVAC gateway series. ACMELEC is the main brand; ME, DK, B19, B27 and B25L identify gateway routes and ordered configurations.

AcmeLink VRF gateway products for smart home, BMS and remote HVAC control integration, with OEM/ODM support for HVAC brands and project buyers.

Factory supply · B2B

Catalogues, samples & wholesale quotations

Supplied from China

ACMELEC manufactures and supplies HVAC controls from Nanjing, China, for distributors, installers and OEM/ODM projects.

Standard MOQ: 60 units/sets

Models, protocols and software versions may be counted separately. Pricing and production lead time depend on the confirmed configuration and quantity.

Sample options

After requirements and payment are confirmed: stock samples approximately 3 working days; functional/protocol configuration 15–20 working days; logo, manual or packaging adjustments approximately 10 working days.

Confirm your application before ordering

Send the complete indoor-unit model, communication connector or wiring photos, required protocol and control functions. Compatibility depends on the exact unit and ordered configuration.

AcmeLink VRF gateway products for smart home, BMS and remote HVAC control integration, with OEM/ODM support for HVAC brands and project buyers.

Choosing the right VRF gateway

Gateway selection depends on the indoor-unit model, communication port, original-controller requirement and target platform. ACMELEC verifies wiring and protocol compatibility before samples or quotations.

OEM options

  • Brand logo and packaging customization
  • WiFi, Zigbee, Modbus, RF433 or 0-10V configurations where applicable
  • Project matching for hotels, apartments, offices and HVAC distributors

Related products

AcmeLink (VRF Gateway) products

Before quotation

Gateway project information

  • HVAC brand, complete models and system quantity
  • Communication ports, wiring and original-controller requirement
  • BMS or host-system type
  • Required functions, addresses and Modbus route

Project-specific configuration

Gateways are matched to the actual HVAC architecture. Protocol, wiring, polarity and addressing must be confirmed before samples.

View samples, MOQ and OEM/ODM policy

Five gateway routes

Compare B19, B27, B25L, ME and DK

Choose the installation architecture first, then match the HVAC interface and required control configuration. The options below belong to specific models and ordered versions.

On smaller screens, swipe the table horizontally to compare all five models.

AcmeLink gateway selection reference
Selection pointB19B27B25LMEDK
Control architectureOne gateway for multiple indoor units on a supported shared system bus.One gateway per indoor unit.One gateway per indoor unit.CN105 module at the confirmed Mitsubishi Electric indoor unit.P1/P2 module on the confirmed Daikin indoor-unit controller route.
HVAC connectionMatched indoor or outdoor communication bus; brand and model dependent.Matched indoor-unit terminals and brand firmware.Matched indoor-unit terminals and brand firmware.Mitsubishi Electric CN105; full tested model and suffix must match.Daikin P1/P2, non-polarized two-wire connection.
Control configurationThe supplied manual covers Aqara Zigbee through a compatible hub. Request matched documents for BMS/Modbus or KNX requirements.RS485, Zigbee, BLE or WiFi options depend on the ordered version and host platform.RS485; UART for optional third-party WiFi, Zigbee or BLE modules. Confirm the application protocol.WiFi; Zigbee; Modbus; WiFi + Modbus; Zigbee + Modbus.Tuya Smart / Smart Life over 2.4 GHz WiFi.
Controller and hubNo additional thermostat for the supported direct-bus route. Aqara integration needs a compatible hub.Original wired-controller coexistence varies by HVAC model and settings.Original-panel coexistence only on supported routes; automatic master/slave adaptation requires HVAC support.Original-controller retention depends on the confirmed installation. Zigbee versions need a matched Tuya hub.Can retain the compatible original wired controller in parallel.
Size and placement106 × 96 × 57 mm; accessible DIN-rail or control-box installation.51 × 53 × 17 mm; suitable back box or indoor-unit service space.85 × 85 × 28 mm; indoor-unit service opening or indoor smart-control box.68 × 58 × 25 mm; beside the confirmed indoor-unit control board.74 × 37 × 23 mm; beside the compatible P1/P2 control route.
Power referenceDC 12 V; 2.0 W.Compatible indoor-unit supply; average 0.5 W.Compatible indoor-unit supply; average 0.5 W. Auxiliary output: DC 8.5 V, maximum 0.7 W before module consumption.Compatible CN105 interface supplies power and communication.Follow the matched DK installation and wiring instructions.
First selection checkFull system topology, bus layout, device count and target hub/BMS.Indoor-unit model, terminals, original controller and commissioning access.Full indoor-unit model, connector, original panel, target host and WeChat commissioning access.Complete indoor-unit model and suffix, CN105 photo and required configuration.Indoor-unit model, P1/P2 terminals and existing wired controller.
Manual and matchingB19 manual (PDF · 11 pages · 15.4 MB)
Check B19 compatibility
B27 manual
Check B27 compatibility
B25L manual
Check B25L compatibility
ME manual (PDF · 16 pages · 20.2 MB)
Check ME compatibility
DK manual
Check DK compatibility

Compatibility depends on the complete equipment models, connection and configuration. Read the B19, B27 and B25L architecture guide for gateway allocation examples.

Matter AC controller options

For a project specifying Matter over Wi-Fi, compare the Mitsubishi Electric CN105 Matter controller and Daikin P1/P2 Matter controller. ME and DK use different indoor-unit interfaces. Confirm the full model and current Matter functions before choosing; see the Matter HVAC product range for heating options.

ACMELEC AcmeLink evidence and support